7. Insert the T-20 thin bladed torx screwdriver into the access hole at the rear of the printer.
8. Fully tighten the T-20 horizontal attachment screw which secures the OMAS to the printer.
9. Clip the OMAS access cover back into place by sliding one edge of the cover into the slot and
then applying enough pressure to it so you can clip it into the other slot.
10. Calibrate the OMAS See OMAS Calibration on page 140.
Interconnect PCA
Removal
358 Chapter 9 Printer part removal and installation ENWW