SE 26.4:01
Cause: Bad contact detected in ISS slot 4 floater
Solution: Try the following operations on the Magenta Cartridge (T7100); the T7100 Monochrome
should not experience this error.
●
Remove the Ink Cartridge and reinstall it into the printer.
●
Replace the Ink Cartridge.
●
Check that the ISS to Cartridge cable is not damaged and is correctly connected to the Ink Supply
Tubes PCA.
●
Replace the ISS to Cartridge cable
ISS to Cartridge Cables on page 308.
SE 26.5:01
Cause: Bad contact detected in ISS slot 5 floater
Solution: Try the following operations on the Gray Cartridge (T7100); the T7100 Monochrome
should not experience this error.
●
Remove the Ink Cartridge and reinstall it into the printer.
●
Replace the Ink Cartridge.
●
Check that the ISS to Cartridge cable is not damaged and is correctly connected to the Ink Supply
Tubes PCA.
●
Replace the ISS to Cartridge cable
ISS to Cartridge Cables on page 308.
SE 27.1:01
Cause: Calibration failed to due to poor performance of the Yellow Printhead (T7100) or Matte Black
Printhead (T7100 Monochrome) in slot 1
Solution: This may impact your print quality. If it becomes unacceptable in the future, clean all
printheads and check their status.
SE 27.2:01
Cause: Calibration failed to due to poor performance of the Yellow Printhead (T7100) or Matte Black
Printhead (T7100 Monochrome) in slot 2
Solution: This may impact your print quality. If it becomes unacceptable in the future, clean all
printheads and check their status.
SE 27.3:01
Cause: Calibration failed to due to poor performance of the Magenta/Cyan Printhead (T7100) or
Dark Gray Printhead (T7100 Monochrome) in slot 3
Solution: This may impact your print quality. If it becomes unacceptable in the future, clean all
printheads and check their status.