6 x SFF SAS Hot Pluggable Hard Drive Bays
A
Slimline Bay: Optional optical or floppy drive
Drive Support
Drive SupportDrive Support
Drive Support
Quantity
QuantityQuantity
Quantity
Supported
SupportedSupported
Supported
Position
PositionPosition
Position
Supported
SupportedSupported
Supported
Controller
ControllerController
Controller
Removable Media
Removable MediaRemovable Media
Removable Media
Slimline 1.44-MB Diskette
Drive
Up to 1
A
Integrated
Slimline 24x IDE CD-ROM
Drive
Up to 1
A
Integrated IDE
Slimline DVD-ROM Drive
(8x/24x) Option Kit
(Servers)
Up to 1
A
Integrated IDE
Slimline DVD/CD-RW
Combo Option Kit
Up to 1
A
Integrated IDE
Slimline DVD-RW Drive
(8X) Option Kit
Up to 1
A
Integrated IDE
Hard Drives
Hard DrivesHard Drives
Hard Drives
NOTE:
NOTE:NOTE:
NOTE:
The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should
operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE:
NOTE:NOTE:
NOTE:
Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
SAS Hot Plug SFF Enterprise (ENT) Drives
SAS Hot Plug SFF Enterprise (ENT) DrivesSAS Hot Plug SFF Enterprise (ENT) Drives
SAS Hot Plug SFF Enterprise (ENT) Drives
Quantity
QuantityQuantity
Quantity
Supported
SupportedSupported
Supported
Position
PositionPosition
Position
Supported
SupportedSupported
Supported
Controller
ControllerController
Controller
300GB 6G SAS 10K DP
300GB 3G SAS 10K DP
146GB 6G SAS 10K DP
146GB 3G SAS 15K DP
146GB 3G SAS 10K DP
72GB 3G SAS 15K DP
72GB 3G SAS 10K DP
6
1-6
HP Smart Array E200i/64MB Controller
HP Smart Array E500/256MB Controller
HP Smart Array P400i/512MB BBWC Controller
HP Smart Array P400i/256MB Controller
HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller
Please see
NOTES
NOTESNOTES
NOTES
below regarding hard drive quantity supported
by Smart Array Controller.
NOTE:
NOTE:NOTE:
NOTE:
The Smart Array E200i Controller can support a maximum of 4 hard drives.
NOTE:
NOTE:NOTE:
NOTE:
The Smart Array P400i Controller can support a maximum of 6 hard drives. To support drives 5 and 6, the optional HP Mini
SAS 4i 13.4 inch/0.35 m cable is required (PN 399546-B21).
NOTE:
NOTE:NOTE:
NOTE:
The Smart Array P600 Controller requires HP SAS 4i to Mini SAS 4i 31 inch/.79 meter cable (PN 411100-B21).