228
Using
the
I-Register
for
Indirect
Control
If
a
number
containing
a
fraction
is
stored
in
the
I-register,
E53
(@
reads
only
the
integer
portion
of
the
number.
Thus,
the
I-register
can
contain
a
number
as
large
as
9.999999999, and
the
@
operation
will
still
execute.
For
example:
5.0000
4.000
3.00
Press
Display
9.999999999
9.999999999
o
Display
is
rounded,
but
number
maintains
its
original
value
inside the
calculator.
2
0
9.999999999
Since
the
HP-67
is
now
9.00000000
in
FIX
mode,
executing
8.0000000
the
subroutine
loop
yields
7.000000
the
illustration
of
fixed
6.00000
point
notation.
The
HP-67
displays
if
the
number
in
the
I-register
is
greater
than
9.999999999
when
a
53
[
instruction
is
executed.
For
example:
Press
Display
100
B
0
Error

Table of Contents