312
Service
and
Maintenance
CAUTION
Operating
the
HP-67
from
the
ac
line
with
the
battery
pack
removed
may
result
in
damage
to
your
calculator.
The
procedure
for
using
the
ac
adapter/recharger
is
as
follows:
1.
If
your
recharger
has
a
line-voltage
select
switch,
make
sure
the
switch
is
set
to
the
proper
voltage.
The
two
line
voltage
ranges
are
86
to
127
volts
and
172
to
254
volts.
CAUTION
Your
HP-67
may
be
damaged
if it
is
connected
to
the
charger
when
the
charger
is
not set
for
the
correct
line
voltage.
2.
Set
the
HP-67
power
switch
to
OFF.
3.
Insert
the
recharger
plug
into
the
rear
connector
of
the
HP-67
and
insert
the
power
plug
into
a
live
power
outlet.
4.
Set
the
power
switch
to
ON.
If
the
W/PRGM-RUN
switch
is
set
to
RUN,
you
should
see
a
display
of
.
5.
Set
the
power
switch
to
OFF
if
you
don’t
want
to
use
the
calculator
while
it
is
charging.
6.
At
the
end
of
the
charging
period,
you
may
continue
to
use
your
HP-67
with
ac
power
or
proceed
to
the
next
step
for
battery-only
operation.
7.
With
the
power
switch
set
to
OFF,
disconnect
the
battery
charger
from
both
the
power
receptable
and
the
HP-67.
CAUTION
The
use
of
a
recharger
other
than
an
HP
recharger
like
the
one
provided
with
your
HP-67
may
result
in
damage
to
your
calculator.

Table of Contents

Other manuals for HP HP-67

Related product manuals