Mounting and enclosure
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
Performance
1000 Mb Latency
< 3.4 µs (FIFO 64-byte packets)
10 Gbps Latency
< 2.1 µs (FIFO 64-byte packets)
Throughput
up to 75.7 million pps
Routing/Switching
capacity
101.8 Gb/s
Switch fabric speed
105.6 Gb/s
Routing table size
10000 entries (IPv4)
MAC address table size
64000 entries
Environment
Operating temperature
32°F to 131°F (0°C to 55°C); 32°F to 104°F (40°C)
when used with any X2 10-GbE
Operating relative
humidity
15% to 95% @ 104°F (40°C), noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
15% to 90% @ 149°F (65°C), noncondensing
Altitude
up to 15,000 ft. (4.6 km)
Acoustic
Power: 57.0 dB, Pressure: 40.5 dB ISO 7779, ISO
9296
Electrical characteristics
Frequency
50 / 60 Hz
Description
The switch automatically adjusts to any voltage
between 100-127 and 200-240 V with either 50 or
60 Hz.
Maximum heat
dissipation
865 BTU/hr (912.9 kJ/hr)
AC voltage
100-127/200-240 VAC
Current
6.6 / 3.0 A
Idle power
94 W
Maximum power rating
616 W
PoE power
398 W
Safety
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity
EN
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated
IEC 61000-4-3; 3 V/m
EFT/Burst
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal
line)
Surge
IEC 61000-4-5; 1 kV/2 kV AC
Conducted
IEC 61000-4-6; 3 V