Menu item Sub-menu item Sub-menu item Values Description
ITB Contact/
Alienation
Tray 2 Pickup Motor
Tray 2 Pickup
Solenoid
Tray 3 Pickup Motor
Tray 3 Pickup
Solenoid
Tray 4 Pickup Motor
Tray 4 Pickup
Solenoid
Tray 5 Pickup Motor
Tray 5 Pickup
Solenoid
Duplexer Reverse
Motor
Duplexer Feed Motor
Duplexer ReFeed
Motor
Paper Transport
Motor
Repeat Once (Default)
Continuous
Determines the number of times the test runs.
Print/Stop Test Continuous value
from 0 to 60,000
milliseconds.
Default: 0
Isolate faults by stopping the device during
the print cycle and observing where in the
process the image degrades. To run the test,
specify a stop time. The next job that is sent
to the device stops at the specified time in the
process.
Color Band Test Test Page Print Prints a page that helps identify arcing in the
high-voltage power supplies.
Copies Continuous value
from 1 to 30.
Default: 1
Specify the number of copies to print for the
Color Band test
Scanner Tests Lower Lamp
Sensors
ADF Input Motor
ADF Input Reverse
Flatbed Motor
ADF Read Motor
A service technician can use this menu item
to diagnose potential problems with the
device scanner.
Table 2-17 Troubleshooting menu (continued)
ENWW Troubleshooting menu 57