Manual sensor and tray/bin manual sensor tests
Use these diagnostic tests to manually test the product sensors, switches.
Manual sensor test
The table in this section lists the sensors and switches available in the Manual Sensor Test.
Use the manual sensor test
The Manual Sensor Test screen shows the sensor number, sensor name, sensor state (active or inactive),
and the number of times the sensor has been toggled (activated).
1. From the Home screen on the product control panel, scroll to and touch the Administration button.
2. Open the following menus:
●
Troubleshooting
●
Diagnostic Tests
●
Manual Sensor Test
3. Touch the sensor number and name on the Manual Sensor Test screen to display a sensor location
graphic on the control-panel display.
4. Activate the desired sensor, and then check the control-panel display to verify the sensor state
(active or inactive).
●
The State virtual LED next to the sensor number and sensor name illuminates green when the
sensor is active.
●
The Toggle virtual LED next to the sensor number and sensor name illuminates green after the
sensor is activated and increments by one each time the sensor is interrupted (activated or
deactivated).
For example, opening the front door increments the PS14 Front door Toggle item count two
times—once when the door is opened, and once when the door is closed.
5. Touch the Reset Sensors button to reset the Toggle count item.
-or-
Touch the Cancel button to exit the Manual Sensor Test screen and return to the Diagnostic Tests
menu.
Table 2-12  Manual sensor diagnostic tests
Sensor or switch Replacement Part number Description
PS14 Front Door RM1-6830-000CN Switch, cable (two required)
PS15 Right door WG8-5696-000CN Photointerrupter
PS3301 HCI feed sensor RM1-8888-000CN Crossing paper feed assembly
PS3305 Tray 4 feed RM1-8876-000CN Paper pickup assembly (left)