6.1.6 Protection of the TSF (FPT)
Restricted forwarding of data to external interfaces (FPT_FDI_EXP.1) 6.1.6.1
FPT_FDI_EXP.1.1
The TSF shall provide the capability to restrict data received on any external
Interface from being forwarded without further processing by the TSF to any Shared-
medium Interface.
Reliable time stamps (FPT_STM.1) 6.1.6.2
FPT_STM.1.1
The TSF shall be able to provide reliable time stamps.
TSF testing (FPT_TST.1) 6.1.6.3
FPT_TST.1.1
The TSF shall run a suite of self tests at the request of the authorised user to
demonstrate the correct operation of
Local Device Sign In - User Access Code verification
LDAP Sign In - LDAP Settings verification
Windows Sign In (via Kerberos) - Windows Settings verification.
FPT_TST.1.2
The TSF shall provide authorised users with the capability to verify the integrity of
Local Device Sign In database
Device Administrator Password
User and administrator authentication configuration data (including
Permission Sets and sign-in method assigned to top-level Control Panel
application).
FPT_TST.1.3
The TSF shall provide authorised users with the capability to verify the integrity of stored
TSF executable code.
6.1.7 TOE access (FTA)
Control Panel TSF-initiated termination (FTA_SSL.3) 6.1.7.1
FTA_SSL.3.1
The TSF shall terminate an a Control Panel interactive session after a any one of:
The user starts any job (if configured by U.ADMINISTRATOR)
10 seconds after a user starts any job and the user agrees to the termination
(if configured by U.ADMINISTRATOR)
20 seconds of user inactivity.