6.
To remove a hard drive from the HDD cage:
a. Remove the four retaining screws (two on the top, two on the bottom) holding the drive in
place (Figure 3-10, 1).
b. Slide the drive out from the HDD cage (Figure 3-10, 2).
Figure 3-10 Removing a non-hot-plug hard drive
7. To replace a hard drive into the HDD cage:
a. Slide the hard drive vertically into the HDD cage (Figure 3-11, 1).
b. Using the provided surplus screws if necessary (Figure 3-11, 2), install four retaining screws
(Figure 3-11, 3).
Figure 3-11 Replacing a non-hot-plug hard drive
8. Re-install the non-hot-plug HDD cage into the server and re-install the six mounting screws.
9. Connect the power and data cables to all hard drives.
10. Replace the access panel and the front bezel.
11. Reconnect the power cord(s).
End of procedure. To remove a non-hot-plug drive, reverse the procedure above.
Removal and replacement procedures 37