6. Properly align the heatsink mounting screws to the system board mounting holes so that the air
flow indicator arrow on the top of the heatsink should point toward the rear of the chassis
(Figure 3-23, 1) and tighten with a screwdriver (Figure 3-23, 2).
CAUTION: Do not over-tighten heatsink mounting screws.
Figure 3-23 Installing the heatsink assembly
7. Install heatsink.
CAUTION: Failure to connect the processor fan cable to the system board may result in damage to
the processor and could cause the server to shut down
without displaying messages.
8. Align the air baffle guide pins with the holes on the chassis support bar and lower it into place.
Figure 3-24 Installing the air baffle
End of procedure.
Removal and replacement procedures 46