EasyManua.ls Logo

HP OmniBook 800CT - Figure 4 - Main Diagnostic Screen

HP OmniBook 800CT
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Figure 4 - Main Diagnostic Screen
Running selected tests
Tests may be initiated individually, or as a group. Some tests may be run at different levels. In
general, tests that can take a long time to be fully checked have levels that permit testing more
quickly while still providing a reasonable level of testing. An unselected test has a <Space>
before the test name. A test at a quick level has a <1> before the test name. A standard level
test has a <2> before the test name. A long test has a <3> before the test name. Every test has
a standard level. Some tests also have a quick level, and some tests also have a long level.
Some have both quick and long.
Menu Status Date Time
2 CPU Ok 08/08 14:36:18
2 Cache Ok 08/08 14:35:20
1 RAM, motherboard 16 MB Ok 08/08 14:36:22
1 RAM, plug in 00 MB Ok 08/08 14:36:23
2 BIOS flash ROMS OK C-F=8676? Altera=E56C? Boot=C600? 08/08 14:36:25
2 CMOS Ok 08/08 14:36:26
Upper PC Card
Lower PC Card
2 Timers Ok 08/08 14:36:26
2 Real time clock Ok 08/08 14:36:30
2 IRQ controller Ok 08/08 14:36:31
2 DMA controller Ok 08/08 14:36:32
IR port
Serial port
Printer port
1 Hard disk 813Mb Ok 08/08 14:36:32
Floppy disk
2 Battery Bat=LiIo (OK) Chg=FC B%=60 Vb=8.17 Ta=57.2 08/08 14:36:33
SCSI loopback
1 Keyboard Ok 08/08 14:36:36
1 HP mouse Ok 08/08 14:36:36
2 Audio Ok 08/08 14:36:39
1 Display Ok 08/08 14:36:42
1 Docked device Ok: NOTHING. 08/08 14:36:42
SCSI CD ROM
SCSI Hard disk
Dock slots
Dock keyboard
Dock PS2 mouse
Dock EEPROM
Keyboard Power-On Selftest
Keyboard IRQ Test
Keyboard Interface Test
+3708 +3695
DSP Chip
DMA Channel
Interrupt Lines
Sound Output Test
Version 04 Jan 97, Bios 97/01/29 RED GREEN BLUE
ARROW keys select tests. ENTER or 1, 2, 3 runs test. Or press SPACE to mark
tests then ENTER to run them. F1 or ? gives help. DIAG /? Shows options.
loops=2/20. Last loop begun at 08/08 14:36:18

Table of Contents