Diagnostic tools and setup utilities 91
Table 12 POST Error Messages
Error-Code Error Message Description / Corrective Action
04F Secondary Master Hard
Disk Error
The IDE/ATAPI device configured as Secondary Master could
not be properly initialized by the BIOS. This message is
typically displayed when the BIOS is trying to detect and
configure IDE/ATAPI devices in POST.
050 Secondary Slave Hard Disk
Error
The IDE/ATAPI device configured as Secondary Slave could
not be properly initialized by the BIOS. This message is
typically displayed when the BIOS is trying to detect and
configure IDE/ATAPI devices in POST.
051 Master Hard Disk Error The IDE/ATAPI device configured as Master in the 3rd IDE
controller could not be properly initialized by the BIOS. This
message is typically displayed when the BIOS is trying to
detect and configure IDE/ATAPI devices in POST.
052 Master Slave Disk Error The IDE/ATAPI device configured as Slave in the 3rd IDE
controller could not be properly initialized by the BIOS. This
message is typically displayed When the BIOS is trying to
detect and configure IDE/ATAPI devices in POST.
603 System Fan 1 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
604 System Fan 2 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
605 System Fan 3 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
606 System Fan 4 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
607 System Fan 5 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
608 System Fan 6 Missing System fan 1 is not installed, user should install the system
fan. The system will shut down.
60F Fan Solution Not Sufficient!
Critical Failure Detected –
System Shutting Down in 15
Second!
The non-redundancy fan is not installed, user should install the
system fan. The system will shut down
601 BMC Not Responding BMC not responding, you can load the optimal default value,
or you must change the LO100 card.
05E Password check failed If user input incorrect password more than three times, then
display this error information and continue to boot. There are
two 'password checked failed'. 05E for setup password.
Checking NVRAM Update
Failed
BIOS could not write to the NVRAM block. This message
appears when the FLASH part is malfunctioning.