HP 460W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with Backplane
Part Number
535684-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100 120 200 208 220 230 240
Maximum Rated Output Wattage
460 460 460 460 460 460 460
Nominal Input Current (A rms)
5.5 4.5 2.6 2.5 2.4 2.3 2.2
Maximum Rated Input Wattage
Rating (Watts)
526 520 505 505 503 503 503
Maximum Rated VA (Volt-Amp)
548 542 527 527 524 524 524
Efficiency (%)
87.5 88.5
91 91
91.5 91.5 91.5
Power Factor
0.97
Leakage Current (mA)
0.42 0.50 0.83 0.87 0.92 0.96 1.00
Maximum Inrush Current (A peak)
30
Maximum Inrush Current duration
(mS)
20
Maximum British Thermal Unit
Rating (BTU-Hr)
1794 1773 1725 1725 1715 1715 1715
HP 365W Hot Plug Redundant Power Supply Kit with Backplane
Part Number
532092-B21 Option Kit
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100 120 200 208 220 230 240
Maximum Rated Output Wattage
320 320 360 360 360 360 360
Nominal Input Current (A rms)
4.15 3.41 2.23 2.16 2.03 1.94 1.86
Maximum Rated Input Wattage
Rating (Watts)
412 406 445 445 444 443 443
Maximum Rated VA (Volt-Amp)
413 407 447 447 446 446 445
Efficiency (%)
77.4 78.5 80.5 80.6 80.7 80.8 81.0
Power Factor
0.99
Leakage Current (mA)
0.75 0.75 0.85 0.90 0.95 0.95 1.00
Maximum Inrush Current (A peak)
35
Maximum Inrush Current duration
(mS)
20
Maximum British Thermal Unit
Rating (BTU-Hr)
1354 1334 1462 1462 1459 1456 1456