EasyManua.ls Logo

HP PROLIANT DL320 G6 - Hard Drive

HP PROLIANT DL320 G6
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal and replacement procedures 27
Hard drive
IMPORTANT: Hot-plug capability and drive LED support are only available when a supported
optional controller is installed in the server.
To remove the component:
1. Back up all data on the hard drive.
2. Power down the server (on page 25).
CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
3. Remove the hard drive.
To replace the component, reverse the removal procedure.
When adding hard drives to the server, observe the following general guidelines:
The system automatically sets all drive numbers.
If only one hard drive is used, install it in the bay with the lowest drive number.
Drives must be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options are
as follows:
The embedded controller supports SATA hard drives and drive LEDs in hot-plug carriers. Hot-plug
operation is not supported.
Optional SAS controllers support hot-plug SAS or SATA hard drives and drive LEDs.
NOTE: ACU does not support mixing SAS and SATA drives in the same logical volume.