EasyManua.ls Logo

HP ProLiant DL320e - Technical Specifications

HP ProLiant DL320e
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Unit
Dimensions
(H x W x D)
4 SFF
1.7 x 17.11 x 15.07 inches (4.32 x 43.46 x 38.30
cm)
2 LFF
1.7 x 17.11 x 15.07 inches (4.32 x 43.46 x 38.30
cm)
Weight
(approximate)
Maximum
(Processor,HDD+ Common
Slot power supply with 2
PCI cards)
4 SFF - 8.0 kg, 17.64 lb
Minimum
(Processor, one NHP hard
drive, ATX power supply,
without any Power Supply)
2 LFF NHP - 7.0 kg, 15.43 lb
Input Requirements
(HP ProLiant 300 W power
supply)
Rated Input Voltage
100 to 127 VAC
200 to 240VAC
Rated Input Current
6 Amps (at 100VAC) to 3 Amps (at 200 VAC)
Rated Input Frequency
50 to 60 Hz
Power Supply Output
(per power supply)
Rated Steady-State Power
300 W (at 100 to 127 VAC),
300 W (at 200 to 240 VAC)
Maximum Peak Power
350 W (at 100 to 127 VAC),
350 W (at 200 to 240 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3048 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
Altitude
Operating
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
QuickSpecs
HP ProLiant DL320e Generation 8 (Gen8) v2
Technical Specifications
DA - 14563 North America — Version 8 — December 13, 2013
Page 43

Other manuals for HP ProLiant DL320e

Related product manuals