Diagnostics and Troubleshooting 
4-54  Compaq ProLiant DL360 Server Maintenance and Service Guide 
 
 
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM 
 
Table 4-17:  Event Messages continued 
Event Type  Event Message  Action 
Power Subsystem 
Power Supply 
Failure 
System Power Supply Failure (Power 
Supply X). 
Replace power supply. 
Power Supply 
Inserted 
System Power Supply Inserted (Power 
Supply X). 
None 
Power Supply 
Removed 
System Power Supply Removed (Power 
Supply X). 
None 
Power Supply 
Not Redundant 
System Power Supplies Not Redundant.  Add power supply. 
System 
Configuration 
Battery Low 
Real-Time Clock Battery Failing.  Replace battery. 
Power Module 
Failure 
A CPU Power Module (System Board, 
Socket X). 
Replace power module. 
Power Module 
Failure 
A CPU Power Module (Slot X, 
Socket X). 
Replace power module. 
Automatic Server Recovery–2 
System Lockup  ASR Lockup Detected: Cause  Call the service provider or Compaq 
for diagnosis. 
Operating System 
System Crash  Blue Screen Trap: [NT] 
Kernal Panic: Cause [UNIX] 
Abnormal Program Termination: Cause 
[NetWare] 
Refer to the documentation for the 
operating system. 
Automatic OS 
Shutdown 
Automatic Operating System Shutdown 
Initiated Due to Fan Failure Condition 
Automatic Operating System Shutdown 
Initiated Due to Overheat Condition 
Fatal Exception (Number X, Cause) 
Refer to the documentation for the 
operating system.