Compaq ProLiant DL360 Server Maintenance and Service Guide 2-1
COMPAQ CONFIDENTIAL Codename: MicroMachine Part Number: 169616-006 Last Saved On: 12/31/01 11:05 AM
2
Removal and Replacement Procedures
This chapter provides subassembly/module-level removal and replacement procedures for
Compaq ProLiant DL360 servers. After completing all necessary removal and replacement
procedures, run the Diagnostics program to verify that all components operate properly.
The following is recommended:
The shipping/ejector key
From the Compaq SmartStart
TM
and Support Software CD:
System Configuration Utility software
Array Diagnostics Utility (ADU)
— Diagnostics software
Electrostatic Discharge Information
A discharge of static electricity can damage static-sensitive devices or microcircuitry. Proper
packaging and grounding techniques are necessary precautions to prevent damage. To
prevent electrostatic damage, observe the following precautions:
Transport products in static-safe containers such as conductive tubes, bags, or boxes.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free
stations.
Cover workstations with approved static-dissipating material. Use a wrist strap connected
to the work surface and properly grounded tools and equipment.
Keep the work area free of nonconductive materials such as ordinary plastic assembly
aids and foam packing.
Always be properly grounded when touching a static-sensitive component or assembly.
Avoid touching pins, leads, or circuitry.
Always place drives PCB assembly-side down.
Use conductive field service tools.