Expansion Slots
Expansion SlotsExpansion Slots
Expansion Slots Expansion Slots
Expansion SlotsExpansion Slots
Expansion Slots
#
##
#
Technology
TechnologyTechnology
Technology
Bus
BusBus
Bus
Width*
Width*Width*
Width*
Connector
ConnectorConnector
Connector
Width
WidthWidth
Width
Form Factor
Form FactorForm Factor
Form Factor
Notes
NotesNotes
Notes
1
PCIe 3.0
x8 x8
Low profile slot
2
PCIe 3.0
x16 x16
Half-length, full-
height slot
*Indicates the number of physical electrical lanes running to the connector.
NOTE:
NOTE:NOTE:
NOTE:
Two PCIe 3.0 expansion slots: (1) Half-length, full-height slot and (1) low-profile slot.
HP Server ROM
HP Server ROMHP Server ROM
HP Server ROM
HP ROM (Read Only Memory) is now digitally signed using HP's Corporate Signing Service. This
signature is verified before the flash process starts, reducing accidental programming and preventing
malicious efforts to corrupt system ROM.
HP ROM provides for essential initialization and validation of hardware components before control is
passed to the customer-installed operating system. The ROM also provides the capability of booting from
various fixed media (HDD, CD-ROM) and removable media (USB), to continue operation to the
operating system.
HP ROM performs very early configuration of the video controller, to allow monitoring of initialization
progress via an attached monitor. If configuration or hardware errors are discovered during this early
phase of hardware initialization, suitable messages are now displayed on the connected monitor.
Additionally, these configuration or hardware errors are logged to the Integrated Management Log (IML)
to assist in diagnosis.
HP's ProLiant ROM is used to configure the following:
Processor and chipset status registers
System memory, memory map, and memory initialization
System hardware configuration (Integrated PCI devices and optional PCIe cards).
Customer-specific BIOS configuration (using the HP ROM-Based Setup Utility (RBSU).
NOTE:
NOTE: NOTE:
NOTE:
For further information, please refer to HP's RBSU (ROM based setup utility) user guide:
www.hp.com/support/rbsu
.
Storage Controller
Storage ControllerStorage Controller
Storage Controller
One of the following
depending on Model
Entry Models
HP Smart Array P420i/ZM (RAID 0/1/1+0)
Base Models
HP Smart Array P420i/1GB with FBWC (RAID 0/1/1+0/5/5+0)
High Performance Models
HP Smart Array P420i/2GB with FBWC (RAID 0/1/1+0/5/5+0)
Energy Star - Base and
Entry Models
HP Smart Array P420i/1GB FBWC (RAID 0/1/1+0/5/5+0)
HP Smart Array P420i/ZM (RAID 0/1/1+0)
QuickSpecs
HP ProLiant DL360p Generation 8 (Gen8)
HP ProLiant DL360p Generation 8 (Gen8)HP ProLiant DL360p Generation 8 (Gen8)
HP ProLiant DL360p Generation 8 (Gen8)
Standard Features
DA - 14211 North America — Version 5 — April 19, 2012
Page 5