Step 3 - add additional memory
Step 3 - add additional memoryStep 3 - add additional memory
Step 3 - add additional memory
Memory
MemoryMemory
Memory
1 GB FBD PC2-5300 2 x 512 MB Kit
397409-B21
2 GB FBD PC2-5300 2 x 1 GB Kit
397411-B21
4 GB FBD PC2-5300 2 x 2 GB Kit
397413-B21
8 GB FBD PC2-5300 2 x 4 GB Kit
397415-B21
NOTE:
NOTE: NOTE:
NOTE:
Base Model, External SCSI and External SATA Models come standard with 1 GB of memory and
is expandable to 4 GB. SAN Storage Model comes standard with 2GB of memory and is expandable to
32GB.
Step 4 - add storage controllers
Step 4 - add storage controllersStep 4 - add storage controllers
Step 4 - add storage controllers
The ProLiant DL380 G5 Storage Server comes per default with one embedded Smart Array P400Controller. Select additional
controllers from the below list only if required.
Storage Controllers
Storage ControllersStorage Controllers
Storage Controllers
NOTE:
NOTE:NOTE:
NOTE:
Please refer to the HP ProLiant DL380 G5 SCSI Cabling Matrix for information
on what's required to cable optional array controllers:
ftp://ftp.compaq.com/pub/products/servers/proliantdl380/dl380g4-cabling-
matrix.pdf
SAS Controllers
SAS ControllersSAS Controllers
SAS Controllers
Smart Array P400 Controller
Smart Array P400 ControllerSmart Array P400 Controller
Smart Array P400 Controller
HP Smart Array P400/256MB Controller
405132-B21
HP Smart Array P400 Controller/512MB and BBWC
411064-B21
512MB Battery-backed cache upgrade
NOTE:
NOTE:NOTE:
NOTE:
For Smart Array P400 Controller.
405148-B21
Battery-backed write cache upgrade
NOTE:
NOTE:NOTE:
NOTE:
For Smart Array P400 Controller.
383280-B21
Smart Array P400 Battery Attach Kit
NOTE:
NOTE: NOTE:
NOTE:
This option kit contains a 24" battery cable and adhesive material for
installing a battery into the server if a Smart Array P400 is integrated outside of the
factory. For all solutions, please refer to the server QuickSpecs and User's Manual for
detailed installation instructions.
417836-B21
Smart Array E200 Controller
Smart Array E200 ControllerSmart Array E200 Controller
Smart Array E200 Controller
HP Smart Array E200/128 Controller
411508-B21
HP Smart Array E200/64 Controller
409180-B21
128-MB BBWC (Battery-Backed Write Cache) Enabler
NOTE:
NOTE:NOTE:
NOTE:
Supports the Smart Array E200 Controller, Smart Array 641 Controller, and
Smart Array 642 Controller.
351580-B21
Smart Array P600 Controller
Smart Array P600 ControllerSmart Array P600 Controller
Smart Array P600 Controller
HP Smart Array P600 Controller
NOTE:
NOTE:NOTE:
NOTE:
Requires Mixed PCI-E/X riser cage.
337972-B21
512 MB Battery-Backed Cache Upgrade
NOTE:
NOTE:NOTE:
NOTE:
This 512-MB Battery-Backed Cache Module upgrade kit supports the Smart
Array P600 Controller and the Smart Array 6400 series Controller.
372538-B21
QuickSpecs
HP ProLiant DL380 G5 Storage Server
HP ProLiant DL380 G5 Storage ServerHP ProLiant DL380 G5 Storage Server
HP ProLiant DL380 G5 Storage Server
Product Configuration Wizard
DA - 12559 North America — Version 1 — September 12, 2006
Page 9