Removal and replacement procedures 49
5.
Power up the recovery server. A 1759 POST message is displayed, stating that valid data was flushed
from the cache. This data is now stored on the drives in the recovery server. You can now transfer the
drives (and controller, if one was used) to another server.
Expansion boards
Half-length expansion board
To remove the component:
1. Power down the server (on page 24).
2. Extend the server from the rack (on page 25).
3. Remove the access panel ("Access panel" on page 29).
4. Disconnect any external cables that are connected to the expansion board.
5. Remove the PCI riser cage ("PCI riser cage" on page 40).
6. Disconnect any internal cables that are connected to the expansion board.
7. Remove the expansion board.
To replace the component, reverse the removal procedure.
Full-length expansion board
To remove the component:
1. Power down the server (on page 24).
2. Extend the server from the rack (on page 25).
3. Remove the access panel ("Access panel" on page 29).
4. Disconnect any external cables that are connected to the expansion board.
5. Remove the PCI riser cage ("PCI riser cage" on page 40).
6. Disconnect any internal cables that are connected to the expansion board.