Removal and Replacement Procedures 29
Item Description Zone Configuration
6 Fan 6 Processor Primary
7 Fan 7 Power supply and
processor
Primary (shared)
8 Fan 8 Power supply Redundant
To remove the component:
1. Extend or remove the server from the rack ("Extending the Server from the
Rack" on page 16
, "Removing the Server from the Rack" on page 18).
2. Remove the access panel ("Removing the Access Panel" on page 19
).
3. Use the fan LEDs ("Hot-Plug Fan LED" on page 101
) and fan locations table
to identify if the fan zone is redundant:
If the fan zone is not operating with redundancy, power down the server.
If the fan zone is operating with redundancy, continue with the next step.
4. Remove the fan.
CAUTION: Do not operate the server for long periods without
the access panel. Operating the server without the access panel results
in improper airflow and improper cooling that can lead to thermal
damage.
HP CONFIDENTIAL
File Name: 291916-6.doc Last Saved On: 2/5/04 2:26 PM