EasyManuals Logo

HP ProLiant DL380e Simple Manual

HP ProLiant DL380e
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Contents 3
Contents
Component identification ............................................................................................................... 7
Front panel components ............................................................................................................................. 7
Front panel LEDs and buttons ............................................................................................................ 9
Rear panel components ............................................................................................................................ 10
Rear panel LEDs and buttons ........................................................................................................... 12
PCIe riser board slot definitions ....................................................................................................... 12
System board components ........................................................................................................................ 13
DIMM slot locations ....................................................................................................................... 14
System maintenance switch ............................................................................................................. 14
NMI header .................................................................................................................................. 15
Drive numbering ..................................................................................................................................... 15
Drive LED definitions ................................................................................................................................ 16
FBWC module LED definitions ................................................................................................................... 17
Fan locations .......................................................................................................................................... 19
T-10/T-15 Torx screwdriver ...................................................................................................................... 19
Operations ................................................................................................................................. 20
Power up the server ................................................................................................................................. 20
Power down the server ............................................................................................................................. 20
Extend the server from the rack ................................................................................................................. 20
Remove the server from the rack ................................................................................................................ 22
Remove the security bezel (optional) .......................................................................................................... 23
Remove the access panel.......................................................................................................................... 23
Install the access panel............................................................................................................................. 23
Remove the air baffle ............................................................................................................................... 24
Install the air baffle .................................................................................................................................. 24
Remove the PCI riser cages ....................................................................................................................... 25
Install the PCI riser cages .......................................................................................................................... 26
Setup ......................................................................................................................................... 28
Optional installation services .................................................................................................................... 28
Rack planning resources........................................................................................................................... 28
Optimum environment .............................................................................................................................. 28
Space and airflow requirements ...................................................................................................... 29
Temperature requirements ............................................................................................................... 29
Power requirements ....................................................................................................................... 30
Electrical grounding requirements .................................................................................................... 30
Connecting a DC power cable to a DC power source ........................................................................ 30
Server warnings and cautions ................................................................................................................... 31
Rack warnings ........................................................................................................................................ 32
Identifying the contents of the server shipping carton .................................................................................... 33
Installing hardware options ....................................................................................................................... 33
Installing the server into the rack ................................................................................................................ 33
Installing the operating system................................................................................................................... 34
Powering on and selecting boot options ..................................................................................................... 35
Registering the server ............................................................................................................................... 36

Other manuals for HP ProLiant DL380e

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL380e and is the answer not in the manual?

HP ProLiant DL380e Specifications

General IconGeneral
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor codeSR0LS
Processor cache10 MB
Processor cores4
Processor modelE5-2403
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2400
Processor socketLGA 1356 (Socket B2)
Processor codenameSandy Bridge EN
Motherboard chipsetIntel C600
Processor frequency1.8 GHz
Processor cache typeSmart Cache
Processor lithography32 nm
Processor manufacturerIntel
Processor package size45 x 42.5 mm
Processor front side bus- MHz
Processor operating modes64-bit
ECC supported by processorYes
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed1
Maximum number of PCI Express lanes24
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorTriple
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)25 GB/s
Maximum internal memory supported by processor375 GB
Memory slots12
Internal memory4 GB
Memory clock speed1333 MHz
Maximum internal memory384 GB
Memory layout (slots x size)1 x 4 GB
HDD size3.5 \
RAID levels0, 1, 0+1, 5, 5+0
HDD interfaceSerial ATA
Total storage capacity0 GB
Maximum storage capacity- TB
Number of HDDs installed0
Cabling technology10/100/1000Base-T(X)
USB 2.0 ports quantity6
PCI Express x8 slots3
PCI Express slots version3.0
Power supply460 W
Redundant power supply (RPS) support-
Chassis typeRack (2U)
Processor ARK ID64615
Intel Identity Protection Technology version0.00
Weight and Dimensions IconWeight and Dimensions
Depth698.5 mm
Width445.5 mm
Height87.4 mm
Weight42990 g

Related product manuals