4.
Close and lock the heatsink retaining latches.
5. Install the air baffle.
6. Install the PCI riser cage ("PCI riser cage" on page 38).
7. Install the access panel ("Access panel" on page 30).
8. Install the server into the rack.
9. Power up the server.
Power supply cage assembly
To remove the component:
1. Power down the server (on page 26).
2. Access the product rear panel (on page 27).
3. Remove all power supplies ("Hot-plug power supply" on page 28).
4. Remove the server from the rack (on page 27).
5. Remove the access panel ("Access panel" on page 30).
6. Remove the PCI riser cage ("PCI riser cage" on page 38).
7. Remove the air baffle ("Air baffle" on page 39).
8. Remove the power supply backplane ("Power supply backplane" on page 35).
9. Loosen the system board thumbscrews, and then slide the system board assembly forward.
Removal and replacement procedures 48