System Unit
Dimensions
(H x W x D)
(with bezel)
3.44" x 17.54" x 29.5" (8.73cm x 44.54cm x 74.93cm)
Weight
(approximate)
Maximum:
(all hard drives,
power supplies,
DIMMs and
processors
installed)
61 lb (27.66 kg)
Minimum:
(one hard drive,
two power
supplies, four
DIMMs, and
two processors
installed)
41.00 lb (18.59 kg)
Input
Requirements
(per power
supply)
Range Line
Voltage
100 - 120 VAC (1200W PS only)
200 - 240 VAC (1200W & 1500W PS)
Rated Input
Current
9.2A (100 VAC), 6.6A (200 VAC) - 1200W PS8.3A
(200 VAC) - 1500W PS
Rated Input
Frequency
50 to 60 Hz
Rated Input
Power
1000 W (120 VAC), 1320 W (230VAC)- 1200W PS
1652 W (at 230 VAC) - 1500W PS
BTU Rating
Maximum
3408 BTU/hr (120 VAC), 4500 BTU/hr (at 230 VAC)
- 1200W PS5637 BTU/hr (230 VAC) - 1500W
PSVAC), 3112 BTU/hr (at 240 VAC) for China Only
Power Supply
Output
(per power
supply)
Rated
Steady-
State Power
For 1400W Power Supply: 1400W (at 100 VAC),
1400W (at 240 VAC), 1400W (at 240 VAC)
For 800W Power Supply: 800W (at 100 VAC),
800W (at 240 VAC), 800W (at 240 VAC) input for
China only
For 500W Power Supply: 500W (at 100 VAC),
500W (at 240 VAC), 500W (at 240 VAC) input for
China only
Maximum
Peak Power
For 1400W Power Supply: 1400W (at 100 to 127
VAC), 1400W (at 200 to 240 1VAC), 1400W (at 240
VAC) input for China only
For 800W Power Supply: 800W (at 100 to 127
VAC), 800W (at 200 to 240 1VAC), 800W (at 240
VAC) input for China only
For 500W Power Supply: 500W (at 100 to 127
VAC), 500W (at 200 to 240 VAC), 500W (at 240
VAC) input for China only
NOTE:
To review typical system power ratings use the
HPE Power Advisor which is available online located at
url:
http://www.hp.com/go/proliant-energy-efficient
or
http://www.hp.com/go/hppoweradvisor
.
System Inlet
Temperature
QuickSpecs
HPE ProLiant DL560 Generation9 (Gen9)
Technical Specifications
DA - 15296 Worldwide QuickSpecs — Version 10 — 6.20.2016
Page 52