Server component identification 82
When the boot device selector switch is set to FLP BOT, the optical drive in the top bay is designated as
the primary optical drive. The diskette drive in the bottom bay is bootable. The server cannot boot from a
diskette drive in the top bay when the boot device selector switch is set to FLP BOT.
NOTE: If two optical drives are installed in the server, the server will first attempt to boot from the primary
optical drive ("Boot device selector switch" on page 81). The boot device selector switch setting determines
which drive is the primary optical drive.
Switch setting Description
FLP TOP (default) Diskette drive in top bay is bootable
Primary optical drive in bottom bay is bootable
FLP BOT Primary optical drive in top bay is bootable
Diskette drive in bottom bay is bootable
Setting the switch to view port 85 codes
To change the display on the Systems Insight Display to view port 84 and 85 codes ("Troubleshooting the
system using port 85 codes" on page 68):
1. Extend the server from the rack ("Extending the server from the rack" on page 26).
2. Remove the access panel ("Removing the access panel" on page 28).
3. Locate the switch on the Systems Insight Display.
4. Set the switch to the P85 position to view port 85 codes.
Systems Insight Display LEDs
The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM might
report server status differently than the health LEDs because the software tracks more system attributes.
The amber Systems Insight Display LEDs are located on the media board. In normal operations, all of the
LEDs are off unless one of the components fails.