HP ProLiant ML10 v2 Server
c04567802 – DA – 15220 North America — Version 1 — March 30, 2015
Tower Dimensions
(H x W x D)
(with feet/bezel)
14.5.x 6.89 x 18.71 in (36.82 x17.5 x 47.52 cm)
Tower Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Input Requirements
(per power supply)
440W at 100 V AC input
440W at 200V AC input
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
Power Supply Output
(per power supply)
350 W (at 100 VAC),
350 W (at 200 VAC)
350 W (at 100 VAC),
350 W (at 200 VAC)
0° to 40°C (32° to 104°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
-30° to 65°C (-22° to 149°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
0 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
3048 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.