EasyManuals Logo

HP ProLiant ML110 Quickspecs

HP ProLiant ML110
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
System Unit
Dimensions
(HxWxD)
(with feet)
14.5 x 6.9 x 16.8 in (36.7 x 17.5 x 42.6 cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
39 lb (17.5 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
23.81 lb (10.8 kg)
Input Requirements
(per power supply)
Rated Line Voltage
90 to 132 VAC,
180 to 264 VAC
Rated Input Current
6 A (at 100 VAC),
3 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
600 W (at 100 VAC),
600 W (at 200 VAC)
Power Specifications
To review typical system power ratings use the Power Calculator which
is available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc/Power%
20Calculator%20Catalog.xls
- Click on the system of interest. Example: DL380 G5
- Follow the instructions of the next screens.
Power Supply Output
(per power supply)
Rated Steady-State
Power
365 W (at 100 VAC),
365 W (at 200 VAC)
Maximum Peak Power
385 W (at 100 VAC),
385 W (at 200 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
QuickSpecs
HP ProLiant ML110 Generation 5
Technical Specifications
DA - 12867 Worldwide QuickSpecs — Version 10 — 4.18.2008
Page 22

Other manuals for HP ProLiant ML110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML110 and is the answer not in the manual?

HP ProLiant ML110 Specifications

General IconGeneral
Product LineProLiant
Server TypeTower
ProcessorIntel Xeon E3-1200 series
ChipsetIntel C202
Memory Slots4
StorageSATA Hard Drives (HDDs) or Solid State Drives (SSDs)
Drive Bays4 LFF or 8 SFF
RAID SupportRAID 0, 1, 10
Form FactorTower
ManagementHP iLO
Operating System SupportWindows Server, Linux, VMware
MemoryDDR3 or DDR4 ECC Unbuffered DIMMs (UDIMMs) (depending on the specific generation)

Related product manuals