System Unit – Rack
Dimensions
(HxWxD)
8.61 x19 x 24 in (21.87 x48.26 x 60.96 cm)
Weight
(approximate)
60 lb (27.24 kg) (without hard drives)
Input Requirements
(per power supply)
Range Line Voltage
100 to 120 VAC/200 to 240 VAC
Rated Input Frequency
50 Hz to 60 Hz
Input Power
538W @ 110 VAC
Rated Input Current
7.4A/3.7A
Line Frequency
50 to 60 Hz
BTU Rating
1,839 BTU/hr
SCSI Connectors
Two internal HD68 connectors
(Support for either two internal, two external, or a mix of internal/external is available.
This is achieved using an internal to external SCSI cable option kit (PN 159547-B22)
and either of the two SCSI knockouts.)
Power Supply Output
Power
(per power supply)
Rated Steady-State Power
500W
Temperature Range
Operating
50° to 95° F (10° to 35° C)
(No direct sustaining sunlight)
Storage (up to one year)
-40° to 158° F (-40° to 70° C)
Maximum Wet Bulb
Temperature
82.4° F (28° C)
Relative Humidity
(non-condensing)
Operating
10% to 90%
Non-operating
5% to 90%
Acoustic Noise
Idle
(Fixed Disk Drives Spinning)
L
WAd (BELS)
6.0
L
pAm (dBA)
46.3
Operating
(Random Seeks to Fixed
Disks)
L
WAd (BELS)
6.0
L
pAm (dBA)
46.5