Resetting System Configuration Settings
It may be necessary at some time to clear and reset system configuration settings. When the
system configuration switch position 6 is set to the on position, the system is prepared to
erase all system configuration settings from both CMOS and nonvolatile RAM (NVRAM):
IMPORTANT: Clearing NVRAM deletes the configuration information. Refer to the HP ProLiant ML350
Generation 3 Server Setup and Installation Guide for complete instructions on configuring the server.
1. Power down the server.
2. Set the system configuration switch position 6 to the on position.
3. Power up the server. All configuration settings are now erased and all system operations
halt.
4. Power down the server.
5. Reset the position 6 switch to the default off position.
6. Power up the server.
7. Reset all system configuration settings.
Refer to Chapter 3 of this guide, “Diagnostic Tools,” or refer to the HP ROM-Based Setup
Utility User Guide found on the server documentation CD for more information on RBSU.