Connectors, Switches, and LEDs
Table 4-7: Hot-Plug SCSI Hard Drive LED Combinations continued
Activity Online Fault Meaning
Off On Off OK to replace the drive online if a predictive
failure alert is received (refer to the
“Predictive Failure Alert” section in the HP
Servers Troubleshooting Guide for details),
provided that the array is configured for
fault tolerance and all other drives in the
array are online.
The drive is online and is configured as part
of an array.
Off On Off OK to replace the drive online if a predictive
failure alert is received (refer to the
“Predictive Failure Alert” section in the HP
Servers Troubleshooting Guide for details),
provided that the array is configured for
fault tolerance and all other drives in the
array are online.
The drive is online and is configured as part
of an array.
On or flashing On Off OK to replace the drive online if a predictive
failure alert is received (refer to the
“Predictive Failure Alert” section in the HP
Servers Troubleshooting Guide for details),
provided that the array is configured for
fault tolerance and all other drives in the
array are online.
The drive is online and is being accessed.
HP ProLiant ML350 Generation 3 Server Maintenance and Service Guide 4-15