Page #22 background imageLoading...
Page #22 background image
22 HP ProLiant ML350 Generation 4p Server Maintenance and Service Guide
2. Push down on the power supply release latch, and remove the power supply
from the server.
CAUTION: To prevent improper cooling and thermal damage,
do not operate the server unless all bays are populated with either a
component or a blank.
To replace the component, reverse the removal procedure.
Hot-plug power supply backplane
To remove the component:
1.
Remove the power supplies from the server ("Hot-plug power supply" on
page 21
).
2. Remove the access panel.
3. Disconnect the cables from the components connected to the power supply
backplane.

Other manuals for HP ProLiant ML350 Generation 4p

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML350 Generation 4p and is the answer not in the manual?

HP ProLiant ML350 Generation 4p Specifications

General IconGeneral
Processor SocketSocket 604
ChipsetIntel E7520
Form FactorTower
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
ProcessorIntel Xeon
MemoryPC2-3200 DDR2 SDRAM
Memory Slots8
StorageSAS or SATA (depending on configuration)
Drive BaysUp to 8 hot-plug drive bays
NetworkEmbedded NC7782 PCI-X Gigabit Server Adapter
Power SupplyRedundant power supply optional
Expansion Slots6 total: 2 PCI-Express, 2 PCI-X