EasyManua.ls Logo

HP ProLiant ML350e - Page 35

HP ProLiant ML350e
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal and replacement procedures 35
10.
Remove the fan.
To replace the component, reverse the removal procedure.
Fan cage
To remove the component:
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 28).
o For rack models, if installed, remove the security bezel (on page 29).
2. Power down the server (on page 27).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, extend the server from the rack (on page 29).
5. Remove the access panel ("Access panel" on page 30).
6. If installed, remove the PCI air baffle ("PCI air baffle" on page 32).
7. Remove any installed full length PCI cards.
8. Remove the system air baffle ("System air baffle" on page 31).
9. Remove the fan cage from the server:

Other manuals for HP ProLiant ML350e