Removal and replacement procedures 60
6.
Install the heatsink.
7. Install the system air baffle.
8. Install the PCI air baffle, if removed.
9. Install the access panel.
10. Do one of the following:
o For tower models, return the server to an upright position.
o For rack models, install the server onto the rails.
11. Connect each power cord to the server.
12. Connect each power cord to the power source.
13. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
14. Do one of the following:
o For tower models, install the bezel.
o For rack models, if removed, install the security bezel.
DIMMs
To remove the component:
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 28).
o For rack models, if installed, remove the security bezel (on page 29).
2. Power down the server (on page 27).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.