Removal and replacement procedures 68
10.
Install the heatsink.
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
11. Install all components and cables removed from the failed system board.
12. Install the fan cage.
13. Install the capacitor pack connecting cable.
14. Install the system air baffle.
15. Install the PCI air baffle, if removed.
16. Install the access panel.
17. Do one of the following:
o For tower models, return the server to an upright position.
o For rack models, install the server onto the rails.
18. Connect each power cord to the server.
19. Connect each power cord to the power source.
20. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
21. Do one of the following:
o For tower models, install the bezel.
o For rack models, if removed, install the security bezel.
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
After you replace the system board, you must re-enter the server serial number and the product ID.
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select the Advanced Options menu.