EasyManuals Logo

HP ProLiant User Manual

HP ProLiant
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Audible Beeps: None
Possible Cause: A media error is detected on a drive and cannot be corrected because of degraded fault
tolerance or a media error at the same location on another drive in the same array. An unrecoverable
read error is returned to the operating system when this block address is read.
Action: Backup and restore the data on the drive. Sequential write operations to the affected blocks
should resolve the media errors.
1717-Slot X Drive Array Controller - Disk Drive(s) Reporting OVERHEATED
Condition
Audible Beeps: None
Possible Cause: The drives listed in this message are currently in an overheated state.
Action: Check the fans and be sure the air flows over the drive. Install the access panel, if removed.
1718-Slot X Drive Array Controller - Device discovery found more devices attached
to this controller than firmware currently supports...
...Some devices are ignored.
Audible Beeps: None
Possible Cause: The firmware does not support the number of devices currently attached to the controller.
Action:
x If release notes indicate that support for additional devices has been added, upgrade to the latest
version of controller firmware.
x Remove some of the devices attached to the controller.
1719-Slot X Drive Array - A controller failure event occurred prior to this power-up
(previous lock-up code = 0x####)
Audible Beeps: None
Possible Cause: A controller failure event occurred before the server powered up.
Action: Install the latest version of controller firmware. If the condition persists, then replace the controller.
1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI:
Port Y: SCSI ID Z.
Audible Beeps: None
Possible Cause: A hard drive SMART predictive failure condition is detected. It may fail at some time in
the future.
Action:
x If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive
and restore all data afterward.
x If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in
the array are online.

Table of Contents

Other manuals for HP ProLiant

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant and is the answer not in the manual?

HP ProLiant Specifications

General IconGeneral
BrandHP
ModelProLiant
CategoryServer
LanguageEnglish

Related product manuals