Mismatched power supplies not supported
Audible Beeps: 1 long, 1 short
Possible Cause: The power supplies installed in the server are not supported in the current configuration.
The server does not support installing more than one type of power supply.
Action: Install supported power supplies in a supported configuration.
For supported power supply configurations, see the server documentation on the HP website
(http://www.hp.com/support
).
Mixed processor speeds detected. Please make sure that all processors are the
same speed. — System Halted!
Audible Beeps: 1 long, 1 short
Description: Mixed processor speeds are not supported.
Action: Refer to the server documentation for supported processors. Be sure that all installed processors
are the same speed.
Network Server Mode Active and No Keyboard Attached
Audible Beeps: None
Possible Cause: A keyboard is not connected. An error has not occurred, but a message is displayed to
indicate the keyboard status.
Action: No action is required.
NMI - Button Pressed!
Audible Beeps: None
Possible Cause: The NMI button was pressed, initiating a memory dump for crash dump analysis.
Action: Reboot the server.
NMI - Undetermined Source
Audible Beeps: None
Possible Cause: An NMI event has occurred.
Action: Reboot the server.
Node Interleaving disabled - Invalid memory configuration
Description: Each node must have the same memory configuration to enable interleaving.
Action: Populate each node with the same memory configuration and enable interleaving in RBSU.

Table of Contents

Other manuals for HP ProLiant

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant and is the answer not in the manual?

HP ProLiant Specifications

General IconGeneral
BrandHP
ModelProLiant
CategoryServer
LanguageEnglish

Related product manuals