SolutionClosed defect summary
Fixed in Fabric OS 6.1.1.Invalid Tx/Rx rate can be computed if a polling cycle takes place when
a domain name has not been assigned.
Fixed in Fabric OS 6.1.1.An EZ Switch Manager validation error occurs on existing zones due
to devices of type initiator+target or unknown being treated like stor-
age.
Fixed in Fabric OS 6.1.1.The Accept CT_IU to GA_NXT Request frame is being rejected by a
third-party storage device because the frame size is 680 bytes.
Fixed in Fabric OS 6.1.1.HP 8/80 FRU faulty status not recovered after connecting to correct
power supply after operating with a single power supply.
Fixed in Fabric OS 6.1.1.A Tape Selective Reset error occurs due to incorrect handling of Early
End Synchronization status.
Fixed in Fabric OS 6.1.1.A FICON Device Level Ack Emulation Processing error occurred.
Fabric OS 6.1.1a fixes
Table 10 lists defects closed in the Fabric OS 6.1.1a firmware release.
Table 10 Fabric OS 6.1.1a closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.1.1a.The tag field of the node identifier command returned, contains the
port number on which the command was received, instead of the tag
field of the device on the other end of the link.
Fixed in Fabric OS 6.1.1a.After systemverification —short is completed on the HP 8/80
SAN Switch, the route is affected on platforms with BI ports.
Fixed in Fabric OS 6.1.1a.Third-party application paths fail with FC Fast Write enabled with bid-
irectional traffic due to out of order or dropped frames.
Fixed in Fabric OS 6.1.1a.Speed negotiation fails on some 4-Gb Quad-Rate, long-wave, 4-km
SFPs.
Fixed in Fabric OS 6.1.1a.Java is running out of memory in WebTools causing sluggish response.
Fixed in Fabric OS 6.1.1a.On a backbone switch with both EX_Ports and VE_Ports, or VEX_Ports,
after hafailover and hareboot, the device on the backbone has
no access to the remote device.
Fixed in Fabric OS 6.1.1a.Need better response message from CAL when the setting of SCC
policy fails.
Fixed in Fabric OS 6.1.1a.When transient failure occurs at the same time as core blade plug in-
sertion, frames could be dropped in the switch, leading to SCSI timeouts
and errors.
24

Other manuals for HP StorageWorks 8/24 - SAN Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 8/24 - SAN Switch and is the answer not in the manual?

HP StorageWorks 8/24 - SAN Switch Specifications

General IconGeneral
BrandHP
ModelStorageWorks 8/24 - SAN Switch
CategorySwitch
LanguageEnglish

Related product manuals