SolutionClosed defect summary
Fixed in Fabric OS 6.1.1.Internal server ports on an embedded platform; traffic may stop due
to loss of buffer credit.
Fixed in Fabric OS 6.1.1.Mixed fabric of McDATA and Brocade switches cannot be managed
if only IPv6 addressing is supported.
Fixed in Fabric OS 6.1.1.HBA is not following Fibre Channel protocol standards, which could
cause a switch reboot.
Fixed in Fabric OS 6.1.1.Problems in an IP network could cause a switch running Fabric OS
5.3.x to panic.
Fixed in Fabric OS 6.1.1.Device with slow initialization sequence may cause the switch to mis-
takenly establish virtual channels on an F_Port.
Fixed in Fabric OS 6.1.1.WebTools zoning breaks when third party storage virtualization appli-
ance is changed to standby mode leading to WebTools hangs.
Fixed in Fabric OS 6.1.1.FICON tape write pipelining selectively resets after CmdRetry to
NoOp sequence to LBY, causing tape job failures.
Fixed in Fabric OS 6.1.1.F_Port link initialization failure exposed by new third-party device be-
havior, where switch continues to send idles after NOS from HBA.
Fixed in Fabric OS 6.1.1.SupportSave command using DCFM does not contain information
from the standby CP.
Fixed in Fabric OS 6.1.1.HP 400 Multi-Protocol Router sends the wrong sense code during tape
backup with pipelining enabled.
Fixed in Fabric OS 6.1.1.WebTools: DCX blade attention LEDs on the switch view GUI window
do not turn amber when the blade needs attention.
Fixed in Fabric OS 6.1.1.FICON PTP VTS selective resets and aborted sequences are caused
by incorrect entry into FICON tape read pipelining.
Fixed in Fabric OS 6.1.1.After renaming a port group name to blank from WebTools, the port
group is deleted.
Fixed in Fabric OS 6.1.1.If EE monitors are restored from flash on a switch that has TopTalker
monitors, there is no warning or error when the TopTalker monitor in-
stallation recovery fails.
Fixed in Fabric OS 6.1.1.The aaaconfig command online help text needs to be corrected to
clearly indicate LDAP cannot be configured while FIPS is enabled.
Fixed in Fabric OS 6.1.1.FR-18i faulted after overnight stress testing.
Fixed in Fabric OS 6.1.1.A TI zone with an invalid (too high) port number can cause a kernel
panic.
Fixed in Fabric OS 6.1.1.ARRd daemon had multiple restarts that ultimately let to a KSWD event.
Fixed in Fabric OS 6.1.1.Fast Write can obtain incorrect FCP command data length if the op-
tional additional CDB length is selected.
Fixed in Fabric OS 6.1.1.Hardware LED shows error status (flashing amber or green), even
though all FRUs are okay.
HP StorageWorks Fabric OS 6.1.2b release notes 23