EasyManua.ls Logo

HP StorageWorks 8/8 - SAN Switch

HP StorageWorks 8/8 - SAN Switch
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
After locating the device ID, disable
and then enable that device.
In rare instances the Name Server DB is out of sync between FOS and
EOS switches in interop mode 3.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Only LDAP certificates with .cer ex-
tension is supported; so use the
--ldapcert option for importing
.cer certificates.
Seccertutil show does not display the contents of certificates with
.cer extension.
Fixed in Fabric OS 6.2.0.
When resetting all the hosts on a blade or slotpoweroff on a blade,
HP StorageWorks 4/256 SAN Director CP reboots due to the Software
Watchdog detecting unexpected termination of the Name Server
daemon.
Fixed in Fabric OS 6.2.0.
Fastboot causes unnecessary FFDC, ERROR, ..., libipadm:
em_AdmSwitchNameGet()
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use portperfshow command.
In some instances of congestion in the Ethernet network, the displayed
VE port utilization value is incorrect.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Block off a badly misbehaving port
that is generating bad traffic on a
switch port that is putting a lot of
stress on the embedded port.
Reject code '0B' response to a QSA frame causes channel definition
errors.
Fixed in Fabric OS 6.2.0.
When the switch name is set using CLI and then read using the Read
Port Address Name x'B2' command to the CUP Port x'FE' it returns the
switch name with a x'7F' attach after the last character in the Switch
Name.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the -o option to override the co-
operative HCL feature.
A failed Pause frame (sent during firmwaredownload process in
Interop Modes 2 and 3), causes a fabric rebuild.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use the -o option.
In some instances, HCL on an HP StorageWorks 8/40 SAN switch in
Interop Mode requires the use of the -o option.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch.
A turboramtest failure does not fully disable the port on an HP
StorageWorks 8/80 SAN switch.
Fixed in Fabric OS 6.2.0.
Web Tools: The HP StorageWorks DC04 SAN Director attention LEDs
on the switch view GUI window do not turn amber when blade needs
attention.
HP StorageWorks Fabric OS 6.2.0g release notes 35

Other manuals for HP StorageWorks 8/8 - SAN Switch

Related product manuals