86
Check SIP User
ID
Always Check, 2 -
Automatic
Account(2)->
Advanced -> Auto
Answer
Number:
0, 1
Auto Answer.0 - no, 1
- yes
P425
×
Account(2)->
Advanced -> Allow
Auto Answer By
Call-Info
Number:
0, 1
Allow Auto Answer
By Call-Info.0 - no, 1 -
yes
P438
×
Account(2)->
Advanced -> Turn
off Speaker on
remote disconnect
Number:
0, 1
Turn off Speaker on
remote disconnect.0
no, 1 yes
P439
×
Account(2)->
Advanced ->
Session Expiration
Number
Session
Expiration(default is
180 seconds)
P434
×
Account(2)->
Advanced ->
Min-SE
Number
Min-Session-Expirati
on(default and
minimum is 90
seconds)
P427
×
Account(2)->
Advanced ->
Caller Request
Timer
Number
Caller Request Timer
(Request for timer
when making
outbound calls) 0 -
No, 1 - Yes
P428
×
Account(2)->
Advanced
->Callee Request
Timer
Number:
0, 1
Callee Request Timer
(when caller supports
timer but did not
request one) 0 - No, 1
- Yes
P429
×
Account(2)->
Advanced ->
Force Timer
Number:
0, 1
Force Timer (use
timer even when
remote party does not
support) 0 - No, 1 -
Yes
P430
×
Account(2) ->
Advanced ->UAC
Specify Refresher
Number:
0-2
UAC Specify
Refresher. 1 - UAC, 2
- UAS, 0 -
omit(Recommended)
P432
×
Account(2)->
Advanced -> UAS
Specify Refresher
Number:
1, 2
UAS Specify
Refresher. 1 - UAC, 2
- UAS(When UAC did
not)