5 Data transmission status
indicator for a GE
electrical port
6 Connection status
indicator for a GE
electrical port
7 Data transmission status
indicator for the
management network
port
8 Connection status
indicator for the
management network
port
9 UID indicator 10 PSU indicator
Indicator Description
Table 5-3 Indicators on the rear panel
Indicator Description
PSU indicator ● O: No power is supplied.
● Blinking green at 1 Hz:
– The input is normal, the server is in standby
state, and the PSU is in MV6 mode (output
voltage is 6.7 V).
– The input is overvoltage or undervoltage.
– The PSU is in deep hibernation mode.
● Blinking green at 4 Hz: The
rmware is being
upgraded online.
● Steady green: The power input and output are
normal.
● Steady orange: The input is normal, but no power
output is supplied.
NOTE
The possible causes of no power output are as follows:
● Power supply overtemperature protection
● Power output overcurrent or short-circuit
● Output overvoltage
● Short-circuit protection
● Device failure (excluding failure of all devices)
UID indicator
The UID indicator helps identify and locate a device.
● O: The device is not being located.
● Blinking blue: The device has been located and is
dierentiated from other devices that have also
been located.
● Steady blue: The device is being located.
NOTE
You can turn on or o the UID indicator by pressing the UID
button or remotely running a command on the iBMC CLI.
Huawei FusionServer Pro 1288H V5 Server
Technical White Paper 5 Hardware Description
Issue 14 (2020-09-03) Copyright © Huawei Technologies Co., Ltd. 17