IPE
Installation Guide
3 Installing an Infrared Waterproof Tube-Type IPC I
Issue 03 (2013-02-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
9
Tool
Appearance
Remark
Drill Template
Foam-rubber
Cushion of installing
bracket
Delivered with the IPC
(Optional)
3.2 Installation Mode
The infrared waterproof tube-type IPC I can be installed on the ceiling or wall. You can select
an installation position based on your requirements. If the IPC is installed on a concrete wall,
install the expansion bolts before installing the bracket. (The installation holes of expansion
bolts must be consistent with those of the bracket.) If the IPC is installed on a wooden wall,
start from Step 4 in section 3 3.3 "Installation Procedure" and use self-tapping screws to
directly install the bracket.
CAUTION
The wall where the bracket is installed must be able to bear at least three times of the total
weight of the bracket and the IPC.
3.3 Installation Procedure
Step 1 Stick the positioning label on the wall, as shown in Figure 3-1.