EasyManua.ls Logo

Huawei PDC-0091V2ACIOA - User Manual

Huawei PDC-0091V2ACIOA
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HUAWEI TECHNOLOGIES CO., LTD.
PDC-0091V2ACIOA
V100R001
Quick Installation Guide
Issue: 04
Part Number: 31505550
Date: 2014-06-25

Questions and Answers

  • J
    John BaileySep 7, 2025
    How to adjust bright or dark local video on Huawei TE30 Conference System?
    • S
      Susan AnthonySep 7, 2025
      If the local video is too bright or too dark when the Huawei TE30 is not in a conference, it might be due to inappropriate video settings. Retain the default values for video parameters on both the TE30 and the display. If the issue persists, the camera may be faulty, and you should send the TE30 to the local distributor for maintenance.
  • J
    James RobertsAug 22, 2025
    How to fix Huawei Conference System endpoint failing to connect to the Internet?
    • B
      Bradley MiddletonAug 22, 2025
      If your Huawei Conference System endpoint can't connect to the internet, it might be due to outdated operating system or Internet Explorer patches. Install the latest patches for both. Also, check your Internet Explorer security settings. If the security level is too high, or your endpoint's IP address isn't on the trusted sites list, adjust the settings. To do this, go to Tools > Internet Options > Security > Trusted sites > Sites in Internet Explorer, add your TE30 IP address, and click OK.
  • J
    Joshua HarrisSep 4, 2025
    Why is the local video in black and white on my Huawei TE30 Conference System?
    • S
      sanderskimberlySep 5, 2025
      If the local video on your Huawei TE30 Conference System is in black and white or blinking, the mode of the video output port might be set incorrectly. Ensure that the mode of the video output port and the cable in use match each other. Also, check that the cable is connected correctly and replace it if necessary.
  • T
    Tyler LeSep 3, 2025
    Why can I only hear the local site during a Huawei TE30 conference?
    • D
      dennis98Sep 3, 2025
      If you can only hear the sound from the local site during a Huawei TE30 conference, it's possible that a loopback test is being performed at the local site. Stop all local and remote loopback tests.
  • M
    Madison ThompsonSep 2, 2025
    What causes Huawei TE30 to fail GK registration after startup?
    • L
      Lauren BurtonSep 2, 2025
      If your Huawei TE30 fails to register with the GK after startup, the parameters used for GK registration might be incorrect. Check the GK address, encryption password, and user name. To correct these settings, navigate to Advanced Settings > Settings > Network > IP > H.323 on the endpoint web interface and make the necessary corrections.
  • J
    Jaime MooneyAug 31, 2025
    How to fix a local VGA display not showing computer desktop connected to Huawei TE30?
    • F
      Frank HaynesAug 31, 2025
      If your local VGA display isn't showing the computer desktop when connected to the Huawei TE30, it might be due to the VGA display's limited capability. Set the resolution and refresh rate of the local output to those supported by the VGA display. The TE30 only supports certain combinations of resolutions and refresh rates, so ensure the computer's VGA input settings are compatible.
  • C
    Craig CurtisAug 30, 2025
    Why is there no audio from the local display during a Huawei TE30 Conference System conference?
    • C
      carlhubbardAug 30, 2025
      If there's no audio from the local display during a Huawei TE30 conference, it could be that the chair site has muted the speaker of the local site. Restore the volume to its default value. If audio is output properly when the audio test is performed, the problem exists at the remote site. The microphone at the remote site may have been muted, or no sound pickup device is connected to the audio source input port.
  • E
    Eric CobbAug 28, 2025
    Why does my Huawei TE30 Conference System show local video but not remote video during a conference?
    • N
      Nicole EvansAug 29, 2025
      If your Huawei TE30 Conference System displays local video but not remote video during a conference, first check if a local or remote loopback test is in progress and stop all tests. If the video bandwidth [frame rate] is set to 0, no video will be sent from the remote site; contact the remote site administrator. If the remote video appears as a blue screen, the remote site might be hiding its video by sending a blue screen; contact the remote site administrator. Also, verify that the video output port is set to display the remote video.
  • M
    michael95Aug 27, 2025
    What to do if Huawei TE30 Conference System display doesn't show video or UI?
    • H
      Henry LinAug 27, 2025
      If your Huawei TE30 Conference System display doesn't show the remote controlled UI or local video when powered on but not in a conference, first check if the display is powered on. If it is, ensure the correct video channel is selected using the remote control. Incorrect video settings on the TE30 or display, such as brightness set to 0, can also cause this; retain the default values for video parameters. Finally, verify that the video cable is securely connected between the TE30 and the display.
  • J
    Johnny FloydAug 26, 2025
    Why can't local and remote sites call each other using site numbers on Huawei Conference System?
    • K
      kmurrayAug 26, 2025
      If the local and remote sites cannot call each other using site numbers on your Huawei Conference System, it may be because either the local or remote site is not registered with a GK. Verify the GK registration settings. Another reason could be that the local or remote endpoint is not connected to an IP network. Ensure that the IP network cable is properly connected and verify the IP network settings.

Overview

This document describes the PDC-0091V2ACIOA V100R001 Power Distribution Cabinet (PDC), a crucial component for managing power in Uninterruptible Power System (UPS) setups. The PDC, also referred to as a Power Distribution Unit (PDU), is designed to work with various Huawei UPS models, including UPS2000-G-6K/10KRTS, UPS2000-G-6K/10KRTL, and UPS2000-G-15K/20KRTL, supporting both three-phase input single-phase output and single-phase input single-phase output configurations.

Function Description

The PDC-0091V2ACIOA serves as a central point for power distribution, ensuring reliable and organized power delivery to connected equipment. It integrates multiple circuit breakers for input and output lines, bypass circuits, and maintenance bypass, enhancing system reliability and safety. The unit facilitates the connection of UPS systems to AC mains, AC loads, and provides communication ports for monitoring and control. Its design allows for flexible installation, either rack-mounted or tower-mounted, to suit different data center or equipment room layouts. The PDC manages power flow, protects against overcurrents, and provides a safe means for system maintenance through its bypass capabilities.

Important Technical Specifications

  • Model: PDC-0091V2ACIOA
  • Applicable UPS Models: UPS2000-G-6K/10KRTS, UPS2000-G-6K/10KRTL, UPS2000-G-15K/20KRTL (supporting Three-Phase Input Single-Phase Output and Single-Phase Input Single-Phase Output).
  • Weight: 13 kg
  • Dimensions (H x W x D): 130 mm x 430 mm x 585 mm
  • Input/Output Circuit Breakers:
    • UPS 1 Mains Input Circuit Breaker
    • UPS 2 Mains Input Circuit Breaker
    • UPS 1 Bypass Input Circuit Breaker
    • UPS 2 Bypass Input Circuit Breaker
    • UPS 1 Output Circuit Breaker
    • UPS 2 Output Circuit Breaker
  • Maintenance Bypass: Includes a dedicated circuit breaker and cover for safe maintenance operations.
  • Output Sockets:
    • Output socket group 1 (250 V AC, 15 A) with corresponding fuses.
    • Output socket group 2 (250 V AC, 10 A) with corresponding fuses.
  • Communication Ports: Control Area Network (CAN) communication ports for checking input and output voltage of the PDU.
  • Cable Specifications (Examples):
    • PDU AC output power cable:
      • 6 mm² (1+1 UPS2000-G-6 KVA parallel system) / 10 mm² (1+1 UPS2000-G-10 KVA parallel system)
      • 16 mm² (2+0 UPS2000-G-6 KVA parallel system) / 16 mm² (2+0 UPS2000-G-10 KVA parallel system)
      • 16 mm² (1+1 UPS2000-G-15 kVA/20 kVA parallel system)
    • PDU bypass input power cable:
      • 6 mm² (1+1 UPS2000-G-6 KVA parallel system) / 10 mm² (1+1 UPS2000-G-10 KVA parallel system)
      • 16 mm² (2+0 UPS2000-G-6 KVA parallel system) / 16 mm² (2+0 UPS2000-G-10 KVA parallel system)
      • 16 mm² (1+1 UPS2000-G-15 kVA/20 kVA parallel system)
    • PDU mains input power cable (for 1+1 UPS2000-G-15 kVA/20 kVA parallel system, three-phase input): 6 mm² (1+1 UPS2000-G-15 kVA/20 kVA parallel system)
    • Maintenance bypass port cable: RVV 4 x 0.5
    • CAN communications port cable: SBYV-100 4 x 2 x 0.5
    • Cable for short-circuiting mains and bypass input N wiring terminals: 6 mm² (M4 to M6 terminals)
  • Torque for Power Cables:
    • UPS2000-G-6 KVA: M4 x 0.7p screw, 1.3 N-m torque
    • UPS2000-G-10 kVA / UPS2000-G-15 kVA / UPS2000-G-20 kVA: M5 x 0.8p screw, 1.5 N-m torque
    • PDU: M5 x 0.8p screw, 1.5 N-m torque

Usage Features

  • Flexible Installation: The PDC supports both rack-mounting (19-inch rack) and tower-mounting configurations.
    • Rack-mounting: Involves installing mounting brackets, then using either floating nuts with common guide rails or adjustable guide rails (optional) with floating nuts. The guide rails are marked 'R' for right and 'L' for left to prevent incorrect installation.
    • Tower-mounting: Requires rotating the PDU front panel logo 90 degrees anticlockwise. Support bases are assembled and placed on the floor, with devices secured on them. The minimum distance between support bases is 280 mm. Rubber plugs are used to seal screw holes after tower-mounting.
  • Cable Management: The PDU provides clearly labeled ports for UPS mains input, bypass input, output, and communication, facilitating organized cable connections. Instructions emphasize connecting cables from bottom to top for devices, and bottom to top for cables within a single device.
  • Safety Precautions: The manual highlights critical safety measures, including using insulated tools, wearing insulation gloves, and using dry power fire extinguishers. It also provides warnings about potential hazards, equipment damage, and personal injury.
  • Personnel Requirements: Only trained and qualified personnel are authorized to install, operate, and maintain the equipment.
  • Movement Regulations: Specific guidelines are provided for moving the PDU based on its weight, with different recommendations for weights less than 18 kg, 18-32 kg, 32-55 kg, and greater than 55 kg. Users are cautioned not to move the PDU by holding its mounting brackets, front panel, or terminal cover.
  • Cable Preparation: Detailed instructions are given for making OT terminals, including using hydraulic pliers of proper specifications, removing burrs, and insulating exposed metals with heat shrink tubing to prevent short circuits.
  • Power-On Procedure: Refers to specific UPS quick installation guides for detailed power-on instructions, indicating a sequential process after all cables are properly connected.

Maintenance Features

  • Maintenance Bypass Functionality: The PDC incorporates a maintenance bypass circuit, allowing the UPS to be taken offline for maintenance without interrupting power to the connected loads.
    • Procedure: Involves opening the maintenance bypass circuit breaker cover, closing the maintenance bypass circuit breaker (circuit breaker 7), opening UPS input and output circuit breakers (circuit breakers 1-6), and disconnecting battery pack hot-swap terminals (if applicable).
    • Alarm Monitoring: The system generates a "Maint. Breaker close" alarm, and the UPS transfers to bypass mode, which can be viewed through the PDU's interface.
    • Voltage Verification: Users are instructed to use a multimeter to verify that UPS input and output voltages are 0 V before proceeding with maintenance, ensuring safety.
  • Modular Design: The presence of separate circuit breakers for UPS 1 and UPS 2 mains input, bypass input, and output, along with distinct output socket groups, suggests a modular approach that simplifies troubleshooting and component replacement.
  • Clear Labeling: The front and rear panels feature clear labeling for all ports, circuit breakers, and indicators, aiding in quick identification and maintenance tasks.
  • Adjustable Support Base (Tower-mounting): The support base length is adjustable, and components can be added to increase its length, providing flexibility for different device configurations and ensuring stability during maintenance.