EasyManua.ls Logo

Huawei SUN2000-75KTL Series - Page 17

Huawei SUN2000-75KTL Series
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Connecting RS485 Communications Cables (48 mm Four-hole Rubber Plug)
Number of
communications cables
Port
Pin
Definition
Pin
Definition
Description
RS485
-1
1
RS485A IN, RS485
differential signal+
2
RS485A OUT, RS485
differential signal+
Used for cascading
solar inverters or
connecting to devices
such as the
SmartLogger
.
3
RS485B IN, RS485
differential signal
4
RS485B OUT, RS485
differential signal
Protection
ground
5
PE, shielding ground
6
PE, shielding ground
N/A
RS485
-2
7
RS485A, RS485
differential signal+
8
RS485B, RS485
differential signal
Used for connecting to
RS485 slave devices.
Installing the RS485 Communications Cable
4.8
The solar inverter supports RS485
communication and MBUS communication. If
the MBUS communication mode is used, you
do not need to connect the communications
cable to the RS485-1 port.
This section describes how to connect three
communications cables.
When routing communications cables,
separate communications cables from power
cables to prevent communication from being
affected.
Pin Definitions of Communications Ports