Technical Specification
GENERAL
MODELS :
Hawk 3 CVHK03FM/CVHK03DFM/
CVHK03FWCVHK03DFW
Hawk 4 CVHK04FM/CVHK04DFM/
CVHK04FWCVHK04DFW
Kestrel CVSKS05FM
Herald 4 CVHH04FMN/CVSHH04FM/
CVHH04FWN/CVSHH04FW
Compact 5 CVC05FM/CVSC05FM/
CVC05FW/CVSC05FW
Slimline 5 CVHH05FMN/CVSHH05FM/
CVHH05FWN/CVSHH05FW
HERALD 6
HERALD 8 SLIMLINE
LOW OUTPUT
INGLENOOK
HIGH OUTPUT
INGLENOOK
HERALD 8
HERALD 14
Energy Efficiency Class
A
A
A+
A
A
A
Nominal Heat Output
Wood
5.4kW
5.0kW
7.3kW
10.2kW
9.1kW
11.9 kW
Nominal Heat Output
Ancit
6.5kW
NA
6.0kW
NA
7.8kW
9.0 kW
Energy Efficiency
101
96
112
105
105
105
Efficiency
Wood
75.9%
72.4%
83.6%
78.4%
78.9%
78.6%
Efficiency
Ancit
67.3%
NA
68.4%
NA
68.5%
79.4%
Mean CO (@13% O₂)
Wood
0.27%
0.25%
0.30%
0.40%
0.38%
0.57%
Mean CO (@13% O₂)
Ancit
0.22%
NA
0.21%
NA
0.35%
0.18%
Appliance Mass
101kg
115kg
148kg
160kg
120kg
145kg
Recommended Fuels
Wood
Seasoned Wood (less than 20% moisture content)
Smokeless
Fuel
Anthracite or a manufactured briquette smokeless fuel
which is suitable for closed door appliances.
Log Length (mm)
380
500
480
500
500
500
FLUES
Mean Flue Gas Temperature
Wood
265°C
271˚C
214˚C
291˚C
293˚C
339˚C
Mean Flue Gas Temperature
Ancit
332˚C
NA
235˚C
NA
304˚C
275˚C
Flue Gas Mass Flow
Wood
5.7 g/s
6.2 g/s
5.5 g/s
7.3 g/s
6.4 g/s
6.4 g/s
Flue Gas Mass Flow
Ancit
7.9 g/s
NA
6.8 g/s
NA
7.2 g/s
7.2 g/s
Flue Outlet Size (Top or Rear Option) (mm)
150
125
150
150
150
150
VENTILATION
- Where leakage is greater than 5m³/hour/m²
- Ventilation normally required = 550mm² per
kW output over 5kW
220m
NONE
1265
mm²
2860
mm²
2255
mm²
3795
mm²
- Where leakage is less than or equal to
5m³/hour/m²
- Ventilation normally required = 550mm² per
kW output
2970
m
2750
mm²
4015
mm²
5610
mm²
5005
mm²
6545
mm²
For further information on ventilation please refer to Building Regulations Document J or your installer.
This stove has been designed and assembled so that it may be used to burn wood logs in a Smoke Control Area.
Find out if you are in a Smoke Control Area by contacting your Local Authority.
The 8 Slimline only has been fitted with a permanent stop that prevents closure of the secondary air slider. Removal
of this will lead to the appliance potentially causing smoke emissions. Without the permanent stop in place the