SYSTEM SETTINGS MENU
The installer can set SYSTEM functions once the thermostat is installed. The
default settings are shown in bold in the following list. Options are listed inside the
parentheses. Example: the default SYSTEM TYPE is CONVENTIONAL with (HEAT
PUMP) as a second option. See pages 28-29 to change these settings.
1. SYSTEM: CONVENTIONAL
(CONVENTIONAL, HEAT PUMP)
2. FURNACE TYPE: GAS/OIL
(GAS/OIL, ELECTRIC)
3. STAGE ONE SPAN (defined on page 26): 2F
(1F, 2F, 3F)
4. STAGE TWO SPAN (not available on 1H/1C
models): 2F
(2F, 3F, 4F, 5F, 6F)
5. AUTO SEASON SPAN: 5F
(3F, 4F, 5F, 6F)
6. TEMPERATURE CALIBRATION: 0F
(-2, -1, 0, +1, +2)
7. STAGE TIMER: 0 minutes
(0, 30)
8. RESIDUAL COOLING TIMER: 30 seconds
(0, 30, 60, 90)
9. RESTORE FACTORY SETTINGS: NO
(YES, NO)
44002-01 r051807