CONNECTING THE WIRES
1. Loosen, but do not remove the terminal screws.
NOTE: A jumper wire is provided, connecting the RH and RC terminals for systems
that do not have both an RH and RC wire. If you have both an RH and RC wire,
remove this jumper; otherwise, leave the jumper in place.
2. Complete wiring diagrams for Conventional HVAC Systems and Heat
Pump Systems are provided on pages 72-74. Match and connect the
wires from the wall to the terminals as shown. Insert wires behind the
black terminal shield. Tighten each screw after the connection is made.
3. Wrap the ends of any extra wires individually in electrical tape and
carefully push them into the wall. Push any excess wire length back
into the wall to prevent interference.