Single switch:
1.  Connect the three grounding wires (green, green/yellow stripe, or bare copper) 
coming from the ceiling, downrod, and hanging bracket.
2.  Connect the white (grounded) wire from the ceiling to the white wire from the fan.
3.  Connect the black (ungrounded) wire from the ceiling to the black wire and blue 
wire from the fan.
1.  Connect the three grounding wires (green, green/yellow stripe, or bare 
copper) coming from the ceiling, downrod, and hanging bracket.
2.  Connect the white (grounded) wire from the ceiling to the white wire from 
the fan.
3.  Connect the black (ungrounded) wire from the ceiling to the black wire from 
the fan.
4.  Connect the second ungrounded (light) wire from the celing to the blue wire 
from the fan.
Dual switches:
Note: To connect the wires, hold the bare metal leads together and place a wire connector over them, then twist clockwise until tight. Turn the splices upward and push them carefully 
back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the 
outlet box.
If you need a different downrod length follow these steps:
Follow steps 1-5 to remove standard downrod pipe
Follow steps 6-10 to reassemble with new downrod
1 2 3 4 5
678910
FAN FALL HAZARD  
To prevent SERIOUS INJURY or DEATH: 
• ALWAYS follow the downrod assembly 
instructions exactly.
• VERIFY the downrod is assembled correctly 
by rmly pulling on the hanger ball.
5
STEP
Green/Yellow Stripe
White
Grounded
Grounding
G
r
e
e
n
/
Y
e
l
l
o
w
 
S
t
r
i
p
e
Black
Blue
Blue
Black
Green/Yellow Stripe
White
Ungrounded
Ungrounded (light)
Grounded
Grounding
G
r
e
e
n
/
Y
e
l
l
o
w
 
S
t
r
i
p
e
All wiring must be in accordance with 
national and local electrical codes ANSI/NFPA 
70.  If you are unfamiliar with wiring or in 
doubt, consult a qualied electrician.
The ceiling fan must be grounded. If the 
ground wire for the installation site is not 
present, immediately STOP installation and 
consult a qualied electrician.
•  Make sure power switch is on.
•  Pull the pull chain to make sure it is on.
•  Push the motor reversing switch rmly left or right to ensure that it is engaged.
•  Check the circuit breaker to ensure the power is turned on.
•  Make sure the blades spin freely.
•  Turn off power from the circuit breaker, then loosen the canopy and check all the connections 
according to the wiring diagram.
•  Check the plug connection in the switch housing.
•  Make sure the blades are properly installed on the blade iron posts.
•  Turn the power off, support the fan carefully, and check that the hanger ball is properly seated.
•  Use the provided balancing kit and instructions to balance the fan.
•  Make sure the blades are properly installed.
•  Check to see if any of the blades are cracked. If so, replace all of the blades.