MAINTENANCE
SCHEDULE
PERFORM THE FOLLOWING MAINTENANCE
Every 2 Years Change hydraulic uid. Use 4 gallons (15 liters) of Hunter’s specially ltered DEXRON III
transmission uid, 148-128-2. NOTE: Oil must be lled when the lift is in its fully lowered
position.
Drain uid from reservoir by dropping pump reservoir with the lift lowered completely.
Clean any metal particles that may be on the magnet
Every 6 Years Hunter Engineering requires that the lifting cables on all 4-Post models be replaced every six
years.
Hunter Service representatives are authorized to perform this service
NOTE
The suggested maintenance above is for normal working conditions. Equipment exposed to unusually dirty
or harsh corrosive conditions such as heavy winter road salt may require more frequent maintenance and
service.
If any of the conditions described above are observed before, during, or after operation of the lift, the operator shall stop
using the lift and report the condition to the supervisor, employer or owner. The lift shall not be used until the cause of the
problem has been determined and the appropriate repairs have been made by qualied automotive lift personnel.
.
Page 15 of 17